To Synchronize Raid After An Unsuccessful Upgrade - Avaya CallPilot 703t Maintenance And Diagnostics

Hide thumbs Also See for CallPilot 703t:
Table of Contents

Advertisement

4. From the right mouse pop-up menu, select Rebuild.

To synchronize RAID after an unsuccessful upgrade

If the upgrade or update has failed, the system needs to be returned to the original
configuration.
1. Restart the server and enter the Ctrl+M utility when prompted during system bootup.
2. From the Management menu select Objects and press Enter.
3. Select Objects → Physical Drive and press Enter.
4. Select FAIL Drive for the drive on Channel 1.
5. Select the drive on Channel 2 (previously taken offline as the backup drive and
6. Exit the utility and press Ctrl+Alt+Delete to reboot the server.
7. Once the system is fully booted, open the Windows MegaRAID console and rebuild
Avaya CallPilot® 703t Server Maintenance and Diagnostics
Example: Channel-2 (0)A1-2-Failed.
Result: When Rebuild is done, the drive status changes to ONLINE and the color
of the icon should change to green. The alarm should stop beeping unless it was
temporarily silenced.
Note:
The process can take up to 1 hour. DO NOT shut down the machine before the
rebuild is complete. If you do reboot or power down during this process, you need
to do
To synchronize RAID after an unsuccessful upgrade
start again. You can monitor the rebuild by opening the Windows MegaRAID
console.
Result: The drive will show as FAIL.
marked 'Failed') and make it ONLINE. Ignore the warning message.
Result: At this point, the drive on the Channel 2 is ONLINE and the one on Channel 1
is marked FAILED.
Result: The system will boot up to the original configuration before the software
upgrade and an audible alarm will indicate the state CRITICAL for the drives. You
can silence the alarm but DO NOT disable it.
the FAIL drive on Channel 1 using the same process indicated in
the RAID after a successful upgrade
upgrade is now complete. The audible alarm, if left on, should automatically stop.
To synchronize RAID after an unsuccessful upgrade
on page 134. Reverting from a failed software
on page 135, then
To synchronize