Task 7-5: Check Alarm Status - Lucent Technologies DEFINITY AUDIX Installation And Administration Manual

For g3i/g3s/g3vs/r5vs/r5si/prologix switches, tn2181 emulation, display set integration
Hide thumbs Also See for DEFINITY AUDIX:
Table of Contents

Advertisement

Installation and Switch Administration for G3i/G3s/G3vs/R5vs/R5si/ProLogix
Switches, TN2181 Emulation, Display Set Integration 585-300-122
5
Initial Definity AUDIX Administration
Check Alarm Status
6. Inform the switch system administrator of any non-unique subscribers in
the administration log. Ask the administrator to change all non-unique
subscriber names in the switch names database to unique names.
7. After the system administrator has changed the non-unique subscriber
names in the switch names database, repeat
Task
When you display the Display Administration-Log screen, the default
values for Start Date and Time on page 1 are the date and time the screen
was last run. To display only the new log entries, use these default values.
If more non-unique subscriber names are found, again ask the switch
system administrator to change all non-unique subscriber names in the
switch names database. Repeat
non-unique names are found.
8. Once the Switch Names audit runs without creating entries for non-unique
subscriber names in the administration log, continue with
Task 5-5: Check Alarm Status
1. With the cursor on the DEFINITY AUDIX command line, type display
alarms and press
The system displays the Alarm Report screen.
a. Connect to the switch and select the data-management option from
the main menu.
b. Create a template by using the add data-template name
command.
c. Retrieve the data and sort it using the name as the key.
d. Use the print out to locate duplicate names.
5-4.
RETURN
Task 5-1J
Task 5-1J
and
.
Issue 1
May 1999
and Steps 1-5 of
Task 5-4
until no
Task
5-5.
5-24