Assigning A Hunt Group; Night Service To An Automated Attendant - Lucent Technologies DEFINITY AUDIX Installation And Administration Manual

For g3i/g3s/g3vs/r5vs/r5si/prologix switches, tn2181 emulation, display set integration
Hide thumbs Also See for DEFINITY AUDIX:
Table of Contents

Advertisement

Installation and Switch Administration for G3i/G3s/G3vs/R5vs/R5si/ProLogix
Switches, TN2181 Emulation, Display Set Integration 585-300-122
6
Optional Switch Feature Administration
Automated Attendant Administration
3. From the attendant console (or administrative voice terminal), activate Call
Forwarding All Calls for the automated attendant extension. Make the
destination the DEFINITY AUDIX hunt group extension.
4. Run the Switch Names Audit from the DEFINITY AUDIX system if the
system is administered in DS integration. Refer to DEFINITY AUDIX
System — Administration (585-300-507) for instructions on running a
Switch Names Audit.

Assigning a Hunt Group

Assign a new hunt group for the automated attendant if there is not a physical
port available on the switch for a station. The hunt group forwards calls to the
DEFINITY AUDIX hunt group. Use the following procedure to assign a hunt group
for the automated attendant.
1. Enter add hunt group number . Obtain the number from
2. Assign the automated attendant group extension (from Step 1) as the
incoming destination for the incoming call trunk groups that will be served
by the automated attendant. If you are not using the automated attendant
as an incoming destination for a trunk group, make sure Auth Code? is
set to n.
3. From the attendant console or administrative voice terminal, activate Call
Forwarding All Calls for the automated attendant extension. Make the
destination the DEFINITY AUDIX hunt group extension.

Night Service to an Automated Attendant

You can set up night service to an automated attendant from an incoming trunk or
from a Listed Directory Number (LDN).
a. Set Group Name to a name that contains the group extension. The
group name can be the group extension, or the group extension
can be embedded in the group name.
b. Set Group Extension to the automated attendant extension on
the worksheet.
c. Set Group Type to ucd (G3V1-V4/R5), or ucd-mia (G3R6 or
greater)
d. Leave Coverage Path blank for best operation, because all calls
are forwarded to the DEFINITY AUDIX hunt group extension.
e. Set the other fields according to the customer requirements.
f. Set Queue? to n
NOTE:
Do not assign any members to this hunt group.
g. Press
.
ENTER
Issue 1
May 1999
6-3
Worksheet
D-2.

Advertisement

Table of Contents
loading

Table of Contents