Migration Procedure
Remove the Tape Drive
!
13. Enter reset system restart to start up the DEFINITY AUDIX voice
messaging system.
14. Call the remote service center to administer the default values for
DEFINITY AUDIX and restore the system to its proper configuration.
15. Continue with
Task F-9: Remove the Tape Drive
Before you administer the new DEFINITY AUDIX and place the system in service,
you must first remove the Tandberg tape drive and re-connect the MO-drive.
1. Remove the tape from the Tandberg tape drive.
2. Enter reset system shutdown to shut down the DEFINITY AUDIX system.
3. Verify that the DEFINITY AUDIX is shut down, then remove it from the
switch carrier.
4. Disconnect the long SCSI cable from the TN568 circuit pack, and
re-connect the MO-disk drive SCSI cable (H600-501 in
5. Slide the DEFINITY AUDIX system back into the switch carrier and lock it
into place.
6. Wait for the system to completely boot up, then log in as craft.
7. Continue with
Task F-10: Verify the DEFINITY
AUDIX Administration
This task is required for all migrations to verify the customer options and make
necessary changes to the DEFINITY AUDIX administration.
Customer options are normally activated before the system is shipped. Complete
the first section of this task,
settings on the System-Parameters Customer-Options screen are correct.
Task F-10A: Display Customer Options
1. At the DEFINITY AUDIX administration terminal, enter display
system-parameters customer options
The system displays the System-Parameters Customer-Options screen.
CAUTION:
Restoring the old configuration on the new system can generate
switch alarms and cause minor switch problems.
Task
F-9.
Task
F-10.
''Display Customer
Figure
Options'', to verify that the
Issue 1
May 1999
F-20
F-10).