Lan Connection - Lucent Technologies DEFINITY AUDIX Installation And Administration Manual

For g3i/g3s/g3vs/r5vs/r5si/prologix switches, tn2181 emulation, display set integration
Hide thumbs Also See for DEFINITY AUDIX:
Table of Contents

Advertisement

Installation and Switch Administration for G3i/G3s/G3vs/R5vs/R5si/ProLogix
Switches, TN2181 Emulation, Display Set Integration 585-300-122
2
Hardware Installation
Connect to the System Adaptor Cable
3. Set the modem options. Refer to
Modems)''
supported modems.
Alarm Connection Via the Alarm Relay
To connect the Definity Audix alarm relay to an alarm device:
1. Connect the DEFINITY AUDIX system cable to the cross-connect field.
Attach the male amphenol connector on a Group 300 cable to the female
amphenol connector on the system cable. The other end of the Group 300
cable should already be attached to the cross-connect field.
2. Perform the cross-connects for the alarm origination/remote maintenance
access connection using the pin-outs listed below.
3. Connect the alarm device to the cross-connect field.
You can connect the switch alarm to the DEFINITY AUDIX alarm relay or to
a different device such as a warning light or buzzer.

LAN Connection

If DEFINITY AUDIX is equipped with LAN connectivity, see
configure the LAN connection. If you are not installing a LAN connection,
proceed to
!
CAUTION:
The LAN connection is only intended for use within a building. To protect
the system from lightning or other external disturbances, a router or LAN
device that provides voltage suppression should be used.
The 104A connecting block is the demarcation point between DEFINITY AUDIX
and the customer-provided LAN. Lucent is responsible for installing the
connecting block and for connecting it to the DEFINITY AUDIX system. The
customer is responsible for connecting the 104A connecting block to the LAN.
Mount the 104A connecting block to the wall field within 25 feet of the switch, and
hard connect eight wires across its two wiring blocks as described below.
1. Arrange the ends of these eight wires into the connecting blocks
2-5).
in
Appendix H
Pin
22
47
Task
2-3.
''Modem Option Settings (for Port C
for a complete list of option settings for all
Definition
relay contact
relay contact
Issue 1
May 1999
2-11
Worksheet C-2