Hardware Installation
Install the DEFINITY AUDIX System Assembly

Slot and Carrier Restrictions

If you must rearrange circuit packs in the switch to accommodate the DEFINITY
AUDIX system assembly, rearrange the packs as indicated on
before proceeding.
Do not use slot 14 (or slot 13 in an EPN control cabinet) for the DEFINITY AUDIX
system if you are installing the system in a System 75 XE or in a single-carrier
cabinet of a DEFINITY G1, G3i, G3r, or G3s.
See the worksheets in
detailed information on rearranging circuit packs and on slot restrictions.

DEFINITY AUDIX System Slots

The DEFINITY AUDIX system assembly requires two contiguous port slots in the
switch carrier (only one if placed in slot 6 of a CMC carrier). In this task, the two
slots are referred to as the first and second slot, with the understanding that they
can be any two contiguous port slots.
The slots are numbered from left to right on the front panel of the switch cabinet,
and from right to left on the rear panel, as shown in
panel, the two port slots are occupied by the DEFINITY AUDIX system assembly
as follows:
The first (left) slot is occupied by the DEFINITY AUDIX hard disk drive and
magneto-optical (MO) disk drive and does not connect to the backplane
of the switch.
The second (right) slot connects the DEFINITY AUDIX TN568 circuit pack
to the backplane of the switch. This is the slot you will connect to the
adaptor cable.
Appendix A, "Switch Carrier Configuration
Worksheet A-2
Worksheets", for
Figure
2-2. Facing the front