Verifying The Emulation And Integration; Types - Lucent Technologies DEFINITY AUDIX Installation And Administration Manual

For g3i/g3s/g3vs/r5vs/r5si/prologix switches, tn2181 emulation, display set integration
Hide thumbs Also See for DEFINITY AUDIX:
Table of Contents

Advertisement

Installation and Switch Administration for G3i/G3s/G3vs/R5vs/R5si/ProLogix
Switches, TN2181 Emulation, Display Set Integration 585-300-122
I
Changing Switch Integrations, Port Emulations, and Number of Voice Ports
Changing from DS Integration — Digital to CL Integration — Digital
9. Enter the current date in the Start Date field and the current time in the
Time field. Leave the Type field blank.
The switch displays Page 2 of the Administration Log. The following log
message appears for each subscriber with new messages in his or her
mailbox:
AUDIX subscriber (ext. XXXXX) may have LWC disabled.
10. Note a specific subscriber for which the preceding message occurs. Then
wait for the message to appear a second time for the same subscriber.
This means that the subscriber's MWI is turned off.

Verifying the Emulation and Integration

Types

Before the change from DS integration to CL integration begins, the remote
service center must change the integration defined for the DEFINITY AUDIX
system. Do the following to be sure the integration has been changed.
1. Log into the DEFINITY AUDIX system.
2. On the DEFINITY AUDIX command line, enter display
system-parameters customer-options
The System Parameters Customer Options screen appears.
3. Check the Port Emulation Type field for the value tn754 or tn2181
4. Check the Switch Integration Type field for dciu-sci
5. If these values are not present in one or both of the fields, call the remote
service center immediately to arrange to change the values.
NOTE:
Reboot the DEFINITY AUDIX system after the integration (and
emulation) designations have been changed and before you do
Verifying the Circuit
Pack.
Issue 1
May 1999
I-10