Verifying The Circuit Pack - Lucent Technologies DEFINITY AUDIX Installation And Administration Manual

For g3i/g3s/g3vs/r5vs/r5si/prologix switches, tn2181 emulation, display set integration
Hide thumbs Also See for DEFINITY AUDIX:
Table of Contents

Advertisement

Installation and Switch Administration for G3i/G3s/G3vs/R5vs/R5si/ProLogix
Switches, TN2181 Emulation, Display Set Integration 585-300-122
I
Changing Switch Integrations, Port Emulations, and Number of Voice Ports
Changing from CL Integration — Analog to DS Integration — Digital
3. Press
Assignments.
change hunt-group 10
Group Number: 10
Group Member Assignments
Ext
Name
1: 12001 AUDIX 1
2: 12002 AUDIX 2
3: 12003 AUDIX 3
4: 12004 AUDIX 4
5: 12005 AUDIX 5
6: 12006 AUDIX 6
7: 12007 AUDIX 7
8: 12008 AUDIX 8
9: 12009 AUDIX 9
10: 12010 AUDIX 10
11: 12011 AUDIX 11
12: 12012 AUDIX 12
13: 12013 AUDIX 13
Figure I-3. Example of a Hunt Group Screen — Group Member Assignments
4. Move the cursor to the Ext field for each voice port you need to remove.
Press
5. Press
6. Enter remove station extension for each voice port you need to remove.

Verifying the Circuit Pack

1. At the switch administration terminal, enter list configuration board slot
where slot is the port location of the DEFINITY AUDIX MFB. If you do not
know the slot location of the DEFINITY AUDIX circuit pack, enter list
configuration to display a list of the circuit packs for the switch.
2. Verify that the circuit pack is recognized as a TN754B circuit pack
(System 75/G1/G3V1) a TN568 circuit pack (R7 or greater) or a TN2181
circuit pack (R6 or less with 12 ports).
to display the Hunt Group screen — Group Member
NEXTPAGE
HUNT GROUP
Group Extension: 12000
to remove data from the field.
CLR-FLD
.
ENTER
Ext
Name
14: 12014 AUDIX 14
15: 12015 AUDIX 15
16: 12016 AUDIX 16
17: ____
18: ____
19: ____
20: ____
21: ____
22: ____
23: ____
24: ____
25: ____
26: ____
Issue 1
May 1999
Page 2 of 5
Group Type: ucd
I-6

Advertisement

Table of Contents
loading