3. CHECK POWER SUPPLY AND GROUND CIRCUIT
Step
1
CHECK POWER SUPPLY.
1) Disconnect the harness connector of body
integrated module.
2) Measure the voltage between harness con-
nector terminal and chassis ground.
Connector & terminal
(i84) No. 34 (+) — Chassis ground (
(B281) No. 2 (+) — Chassis ground (
2
CHECK GROUND CIRCUIT.
Measure the resistance between harness con-
nector terminal and chassis ground.
Connector & terminal
(B280) No. 22 — Chassis ground:
(B281) No. 8, 9, 22 — Chassis ground:
4. CHECK DOOR LOCK SWITCH
Step
1
CHECK DOOR LOCK SWITCH.
Check the input from door lock switch to body
integrated module using Subaru Select Moni-
tor.
1) Connect the Subaru Select Monitor to data
link connector.
2) Turn the ignition switch to ON.
3) Select {Integ ⋅ unit} from main menu.
4) Select {Current Data Display & Save}.
5) Check the input to body integrated module
by operating the door lock switch.
2
CHECK DOOR LOCK SWITCH CIRCUIT.
1) Disconnect the body integrated module
harness connector.
2) Measure the resistance between the har-
ness connector terminal and chassis ground
when moving the door lock switch to LOCK.
Connector & terminal
(i84) No. 15 — Chassis ground:
3
CHECK DOOR LOCK SWITCH CIRCUIT.
Measure the resistance between the harness
connector terminal and chassis ground when
the door lock switch is moved to UNLOCK.
Connector & terminal
(i84) No. 29 — Chassis ground:
4
CHECK DOOR LOCK SWITCH.
1) Disconnect the door lock switch harness
connector.
2) Measure the resistance between the door
lock switch terminals when moving the door
lock switch to LOCK.
Connector & terminal
LHD model:
(D7) No. 4 — No. 7:
RHD model:
(D7) No. 4 — No. 14:
Door Lock Control System
Is the voltage more than 10 V? Go to step 2.
):
):
Is the resistance less than 10
Ω?
Is the normal input signal dis-
played when the door lock
switch is moved to LOCK/
UNLOCK?
Is the resistance less than 10
Ω?
Is the resistance less than 10
Ω?
Is the resistance less than 1
Ω?
SL-11
Check
The power supply
and ground circuit
are OK.
Check
The door lock
switch is OK.
Go to step 3.
The door lock
switch is OK.
Go to step 5.
SECURITY AND LOCKS
Yes
No
Check the harness
for open or short
circuit between
body integrated
module and fuse.
Repair the har-
ness.
Yes
No
Go to step 2.
Go to step 4.
Go to step 4.
Replace the door
lock switch.

Advertisement