Electrical Specifications

Input circuit
Item
Specifications
Model
ZW-CE10T
Input type
NPN
Input voltage
DC24 V10 % (21.6 to 26.4 V)
Input current
7 mA Typ. (DC24 V)
*1
ON voltage/ON current
19 V min./3 mA min.
*2
OFF voltage/OFF current
5 V max./1 mA max.
ON delay
0.1 ms max.
OFF delay
0.1 ms max.
*3
Internal circuit diagram
+
*1 ON voltage/ON current
This is the voltage value or current value that makes the signal go OFF to ON.
The ON voltage value becomes the potential difference between COM IN 1/2 and the input terminals.
*2 OFF voltage/OFF current
This is the voltage value or current value that makes the signal go ON to OFF.
The OFF voltage value becomes the potential difference between COM IN 1/2 and the input terminals.
*3 Below is a table giving the COM_IN (input common) and input signal connection correspondence.
Terminal
COM_IN1
name
TIMING1
RESET1
Input terminal
name
ZERO1
LED OFF1
Important
Chattering countermeasures
• The sensor is designed with functions to deal with chattering, but if chattering of 100 s or more occurs, incorrect
input due to chattering cannot be prevented. (Input signal changes of less than 100 s are ignored. The input signal
is applied when the same level is maintained for 100 s or longer.)
• Always use non-contact relays (SSR, PLC transistor output) for input signals. If contact relays are used, contact
bounding may turn ON a TIMING input again during measuring.
ZW User's Manual
Input
terminals
3.3 kΩ
COM_IN1/2
COM_IN2
BANK_SEL1
BANK_SEL2
BANK_SEL3
LOGGING
ZW-CE15T
PNP
DC24 V10 % (21.6 to 26.4 V)
7 mA Typ. (DC24 V)
19 V min./3 mA min.
5 V max./1 mA max.
0.1 ms max.
0.1 ms max.
Input
terminals
3.3 kΩ
+
COM_IN1/2
49