Bank Switching
BANK_SEL input
(BANK_SEL1/2/3)
BANK_SEL output
(BANK_OUT1/2/3)
ON
BUSY output
OFF
ON
ENABLE output
OFF
Measurement
Item
T7
Input response time
T8
Bank switching time
T9
Measurement start response time
Explanation of operations
(1) The BANK_SEL signal is switched to the bank number to switch to.
(2) After the input response time, the measurement stops and the BUSY output is turned ON, then the bank
switching operation is started.
(3) After bank switching ends, the BUSY output is turned OFF and the BANK_ OUT output is switched.
(4) Measurement is restarted and the ENABLE output is turned ON.
LED OFF
ON
LED OFF input
OFF
Turn ON
LED
ON
ENABLE output
OFF
Measurement
Measurement
Item
T9
Measurement start response time
T10
LED OFF input minimum time
T11
Time of receiving LED OFF input
ENABLE response time after LEDs are turned OFF 
T12
Explanation of operations
(1) The LED OFF input is turned ON.
(2) After the LED OFF input is turned ON, the LEDs are turned OFF.
(3) After the LEDs are turned OFF, the ENABLE output is turned OFF.
(4) The LED OFF input is turned OFF.
(5) After the LED OFF input is turned OFF, the LEDs are turned ON.
(6) After the LEDs are lit up, measurement is restarted and the ENABLE output is turned ON.
156
Parallel I/O connection
(1)
(2)
T7
T8
Measurement
Clamp
(1)
(2)
(3)
(4)
(5)
T10
T11
T12
T11
Turn OFF
Clamp
(3)
(4)
T9
Measurement
Min.
3 × T0
(6)
T9
Turn ON
Measurement
Min.
3 × T0
100 s
Max.
200 ms
100 ms
Depends on the set conditions
Max.
Depends on the set conditions
100 s
2 × T0
ZW User's Manual

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-ce1*tZw-c1*t

Table of Contents