Hold (auto peak/auto bottom/auto peak-to-peak)
ON
RESET input
OFF
ON
BUSY output
OFF
Judgment output
(HIGH/PASS/LOW)
Analog output
Item
T3
Response time of analog output
T4
TIMING input/RESET input minimum time
T5
Input response time
Explanation of operations
(1) The peak value is updated and the judgment result is output.
(2) After the judgment result output, the analog output is updated.
(3) The RESET input is turned ON. If the RESET input is turned ON during the RESET input minimum time, the
measured value is reset.
(4) The judgment result is reset.The BUSY output is turned OFF.
(5) After the judgment result reset, the analog output is reset.
(6) The RESET input is turned OFF.
(7) The BUSY output is turned ON.
Important
When the setting for non-measurement is "CLAMP", if the sampling value is an abnormal value or an undetermined
*
value
, sampling is not executed. If sampling has been started, it is stopped. The output value is as follows.
• Hold the clamp value.
• The BUSY signal is turned OFF.
• To start and continue sampling even if a sampling value is an abnormal value or an undetermined value, set "KEEP"
as the non-measurement setting.
*: After the start of measurement, if measurement results are not obtained the number of times required to take the
average, the measurement result is not applied.
154
Parallel I/O connection
(1) (2)
T3
Min.
3ms+T0
2ms+T0
(3)
(4) (5)
(6)
(7)
T4
T3
T5
T5
Max.
0.1 ms
3ms+T0 × 2
ZW User's Manual