Push in and hold the release button next to the
terminal hole using a screwdriver while pushing the
wire fully into the terminal hole and remove the
screwdriver.
After the connection has been established, pull the wire
gently, to make sure that the connection has been made
securely.
3
Reinstall the Analog output terminal block to the
Sensor Controller.
24 V input terminal block
Used for 24 VDC power supply.
Compatible cable specifications: AWG 12 to 26, pin processed length: 10 mm
Class
Name
Power Supply
DC24V (+)
DC24V (-)
Important
• Wiring with the power on could result in a short-circuit or electric shock. Wire with the power off.
• Wire the power supply separate from other devices. Wiring together with other devices or using the same duct
could cause a false operation or damage the sensor.
• Do not turn off the power during initial processing immediately after the Sensor Controller power is turned on, as the
memory inside the Sensor Controller is being accessed. This may corrupt the data.
• Securely fasten the terminal block to prevent injury when you press in the release button with a screwdriver.
• The length of Cables should be less than 30 m.
ZW User's Manual
No.
Signal name
1
DC24V (-)
2
DC24V (+)
Description
Terminal for external power supply (24 V)
Terminal for external power supply (0 V)
Release button
Terminal hole
Wiring