Setting Filters

Set the filter condition when filtering information obtained from the sensor before output.
The following types of filters can be set depending on purpose.
Displacement
Waveform when
Smooth
filter is not set
Median filter
[MEDIAN]
Average filter
[AVE]
Displacement
Differ filter
0
[DIFFER]
Waveform when
filter is not set
Frequency filter
[FREQ]
Three frequency variations
are mixed.
ZW User's Manual
Spike-like changes are
removed.
Changes are smoothed
out.
Changes are extracted to
eliminate displacement value.
Lowpass filter [LOPASS]
Sudden changes are removed.
Highpass filter [HIPASS]
Gradual changes are removed.
Bandpass filter [BDPASS]
A given change is detected.
Setting the Output Conditions