Hold (sampling)
(1)
ON
TIMING input
OFF
ON
RESET input
OFF
ON
BUSY output
OFF
Judgment output
(HIGH/PASS/LOW)
Analog output
Item
T3
Response time of analog output
T4
TIMING input/RESET input minimum time
T5
Input response time
Explanation of operations
(1) The TIMING input is turned ON.
(2) During the TIMING input minimum time, when the TIMING input is ON, sampling is started and the BUSY
output is turned ON. The measurement result is sampled and the judgment result is output.
(3) After the judgment result output, the analog output is updated.
(4) The RESET input is turned ON. If the RESET input is turned ON during the RESET input minimum time, the
measured value is reset.
(5) The judgment result and is reset.
(6) After the judgment result output, the analog output is reset.
(7) The RESET input is turned OFF.
Important
When the setting for non-measurement is "CLAMP", if the sampling value is an abnormal value or an undetermined
*
value
, sampling is not executed. The output value is as follows.
• Hold the clamp value.
• The BUSY signal is not turned ON.
*: After the start of measurement, if measurement results are not obtained the number of times required to take the
average, the measurement result is not applied.
ZW User's Manual
(2)
(3)
T4
T5
T3
Min.
3ms+T0
2ms+T0
(7)
(4)
(5)
(6)
T4
T5
T3
Max.
0.1 ms
3ms+T0 × 2
Parallel I/O connection