Omron ZW-C1*AT User Manual page 69

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

Important
• When a zero reset is executed, the analog output becomes the voltage or current value at the center of the two
preset points. Analog output becomes roughly 0 V or 12 mA when focus is not set.
Setting Monitor Focus p.142
• The Zero Reset function can also be executed by supplying a ZERO signal to the 32-pole extension connector.
32-pole extension connector p.44
• The Zero Reset function can also be executed by turning ON the EtherCAT ZERO input signal.
Zero reset execution p.166 p.173
Canceling Zero Reset
1
Press and hold the
seconds.
Important
• The Zero Reset function can also be executed by supplying a ZERO signal to the 32-pole extension connector.
32-pole extension connector p.44
ZERO input p.139
• The canceling Zero Reset function can also be executed by turning ON the EtherCAT ZEROCLR input signal.
Zero reset cancel p.166 p.173
ZW User's Manual
key for two
Perform the Zero Reset
67

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-ce1*tZw-c1*t

Table of Contents