In the case in the figure above, the memory map will be as follows.
Position Control Unit to ZW
CIO3800
Node 17
ZW command area (10 words)
CIO3811
CIO3812
Node 18
ZW command area (10 words)
CIO3823
Refer to the CJ-series Position Control Units Operation Manual (Cat. No. W487) for details on I/O memory
assignment methods.
If you connect more than one ZW Sensor to an OMRON Position Control Unit, the following addresses in the
memory map are assigned in order for the I/O areas.
Set the node address setting switches on the Sensors to 0 to automatically set up the network. Node
addresses 17 and higher will be automatically set for the remote I/O.
For the Position Control Unit, the areas are set only for node 17 (which has the first area for each of the three
memory areas).
To access data from another node from a ladder program, add the correct offset from the first word of the first
area for node 17 and access the resulting address.
ZW User's Manual
ZW to Position Control Unit
CIO3900
Node 17
ZW response area (10 words)
CIO3911
Node 17
ZW data output area (16 words)
CIO3927
CIO3928
Node 18
ZW command area (10 words)
CIO3940
Node 18
ZW data output area (16 words)
CIO3955