Note
Clamp values can also be set with key operations on the Sensor Controller.
Setting the Clamp Value p.345

Settings for Bank Control

This section describes the settings for controlling banks by using parallel I/O.
Selecting banks
The bank is selected in combinations of the bank select input signals (BANK_SEL1 to 3).
Bank selection input 1
(BANK_SEL1)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
Important
• Bank switching is begun 0.2 seconds after the input state changes.
• At most it takes about 100ms to switch banks.
• During bank switching, the BUSY output becomes ON.
• If the bank mode is set to [JUDGE], the bank cannot be switched at the external signal input because the number of
banks increases to 32.
Outputting the currently selected bank number
The currently selected bank number is output.
The output bank number depends on the combination of the bank number output signals (BANK_OUT1 to 3).
Bank number output 1
(BANK_OUT1)
OFF
ON
OFF
ON
OFF
ON
OFF
ON
150
Parallel I/O connection
Bank selection input 2
Bank selection input 3
(BANK_SEL2)
(BANK_SEL3)
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
Bank number output 2
Bank number output 3
(BANK_OUT2)
(BANK_OUT3)
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
Selected bank
BANK1
BANK2
BANK3
BANK4
BANK5
BANK6
BANK7
BANK8
Output bank
BANK1
BANK2
BANK3
BANK4
BANK5
BANK6
BANK7
BANK8
ZW User's Manual