Sub-index 1: Non-Measurement Mode
Setting range: 0 to 1
Size: 4 bytes (U32)
Sub-index 2: Analog Clamp Output
Setting range:
Size: 4 bytes (U32)
Sub-index 3: Binary Clamp Output
Setting range: 0 to 1
Size: 4 bytes (U32)
• Data relating to processing item "processing at non-measurement" is stored.
3130 hex
Sub-index 0: Number of entries
Setting range:
Size: 1 byte (U8)
Sub-index 1: Monitor Focus Mode
Setting range: 0 to 1
Size: 4 bytes (U32)
Sub-index 2 to 3: Monitor Focus Output Position 1 to 2
Setting range: -999999999 to
999999999
Size: 4 bytes (INT32)
Sub-index 4: Monitor Focus Current Low Limit
Setting range: 4 to 20
Size: 4 bytes (INT32)
Sub-index 5: Monitor Focus Current High Limit
Setting range: 4 to 20
Size: 4 bytes (INT32)
Sub-index 6: Monitor Focus Voltage Low Limit
Setting range: -10 to 10
Size: 4 bytes (INT32)
Sub-index 7: Monitor Focus Voltage High Limit
Setting range: -10 to 10
Size: 4 bytes (INT32)
Sub-index 8: Analog Output Adjustment Mode
Setting range: 0 to 1
Size: 4 bytes (U32)
Sub-index 9: Analog Output Adjustment Span
Setting range:
Size: 4 bytes (INT32)
Sub-index 10: Analog Output Adjustment Offset
Setting range:
Size: 4 bytes (INT32)
422
Object Dictionary
Unit:
Access: RW
Unit:
Access: RW
Unit:
Access: RW
Analog Output
Unit:
Access: RO
Unit:
Access: RW
Unit: nm
Access: RW
Unit: mA
Access: RW
Unit: mA
Access: RW
Unit: V
Access: RW
Unit: V
Access: RW
Unit:
Access: RW
Unit:
Access: RW
Unit:
Access: RW
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
Factory setting:
PDO map: Not possible
ZW User's Manual