Signal
SYNCFLG
READY
RUN
ERR
BANKOUT1_A to E
HOLDSTAT1
RESETSTAT1
LIGHT1
STABILITY1
ENABLE1
GATE1
OR1
HIGH1_T1-4
PASS1_T1-4
LOW1_T1-4
174
EtherCAT Connection
Signal name
Function
Measurement
Turns ON when the displacement sensor executes measurement
synchronization completion
synchronization processing and the state changes to one where normal
measured values can be output.
Automatically turns OFF if the measurement synchronization signal (SYNC
signal) from the user (Controller) turns OFF.
Ready
Turns OFF when the displacement sensor cannot execute control commands
or measurement synchronization processing.
Turns ON when the displacement sensor can execute control commands or
measurement synchronization processing.
Run screen
Turns ON when the displacement sensor is in the RUN mode.
Turns OFF when the displacement sensor is in the FUN mode.
Error
Turns ON when a displacement sensor error is detected.
Turns OFF when the displacement sensor is normal.
After it turns ON, it never turns OFF until the error clear signal (ERCLR signal)
from the user (Controller) turns ON.
Current bank number
This outputs the currently specified bank number.
It expresses the bank number in combinations of BANKOUTx_A to E.
(For details of combinations, see Reference.)
Hold execution status
Turns ON when the displacement sensor is in the hold sampling period.
Turns OFF when the displacement sensor is outside the hold sampling period.
Reset execution state
Turns ON when the displacement sensor is in the reset execution state.
Turns OFF when the displacement sensor is in the reset non-execution state.
Logical beam lighting state
Turns ON when the logical beam is lit.
Turns OFF when the logical beam is out.
Measurement position
Turns ON when the measured value is in the measuring range.
Turns OFF when the measured value is outside the measuring range.
Measurement state
Turns ON when the displacement sensor is ready for measurement.
Turns OFF when the displacement sensor cannot measure (excessive or
insufficient received light, outside measuring range, Calibration ROM not
mounted, during FUN mode non-measurement).
Data output completed
Turns ON when the displacement sensor completes control data output when
hold is set.
The displacement sensor automatically turns OFF one Gate period after
turning ON.
Overall judgment result
Turns ON when even one of the judgment result of the displacement sensor
TASK1 to 4 is other than PASS.
Turns OFF when all of the judgment result of the displacement sensor TASK1
to 4 is PASS.
HIGH output
Turns ON when the judgment result of the displacement sensor TASK1 to 4 is
HIGH (HIGH threshold < measured value).
Turns OFF when the judgment result of the displacement sensor TASK1 to 4
is other than HIGH.
PASS Output
Turns ON when the judgment result of the displacement sensor TASK1 to 4 is
PASS (LOW threshold  measured value  HIGH threshold).
Turns OFF when the judgment result of the displacement sensor TASK1 to 4
is other than PASS.
LOW output
Turns ON when the judgment result of the displacement sensor TASK1 to 4 is
LOW (LOW threshold > measured value).
Turns OFF when the judgment result of the displacement sensor TASK1 to 4
is other than LOW.
ZW User's Manual