Omron ZW-C1*AT User Manual page 277

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

Event name
Linearity correction data read error
Meaning
Reading of the displacement sensor linearity correction data was not executed correctly.
Source
EtherCAT master function module
Error attributes
Level
Effects
User program
Indicators
EtherCAT NET RUN
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
Calibration ROM not inserted
Calibration ROM damage
Attached
None
information
Precautions/
As a provisional measure, the measurement can be resumed using the data of the previously read Calibration
Remarks
ROM.
<Operation method>
With error code 3 displayed on the sub-display, hold down the Mode switching key, then when [OK/CAN] is
displayed, press the ZERO/SET key.
<Cautions>
• When using this method, always check the serial number of the previously read Calibration ROM in "controller
information," then check that it matches the Sensor Head side serial number. Measurement will not be correct
unless they match.
• When restarting the main unit, perform the same operations again.
• This operation is disabled for a displacement sensor into which no Calibration ROM has ever been inserted
and started up.
Event name
System setting error
Meaning
The system settings saved to the displacement sensor are corrupt.
Source
EtherCAT master function module
Error attributes
Level
Effects
User program
Indicators
EtherCAT NET RUN
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
The displacement sensor power
was turned OFF during saving/
loading of system settings.
Attached
None
information
Precautions/
None
Remarks
ZW User's Manual
Source details
Minor fault
Recovery
Continues
Operation
EtherCAT NET ERR
Data type
Correction
Turn the displacement sensor OFF,
insert the Calibration ROM and turn
the sensor ON again.
Calibration ROM may be broken.
Please contact an OMRON branch
or sales office.
Source details
Minor fault
Recovery
Continues
Operation
EtherCAT NET ERR
Data type
Correction
After holding down the Mode
switching key, press the ZERO/SET
key to clear the system settings and
the bank data, then resume the
starting process.
Event code
14B10000Hex
Slave
Detection
timing
Error reset
Log category
(after
cancellation of
slave error)
An error message is displayed on the displacement
sensor's digital display, and the ALARM output of
parallel I/O turns ON. The displacement sensor is in a
stopped state until it is restarted.
EtherCAT LINK/ACT
Name
Prevention
Event code
14B20000Hex
Slave
Detection
timing
Error reset
Log category
(after
cancellation of
slave error)
An error message is displayed on the displacement
sensor's digital display, and the ALARM output of
parallel I/O turns ON. The displacement sensor is in a
stopped state until it is restarted.
EtherCAT LINK/ACT
Name
Prevention
Do not turn the displacement
sensor OFF during saving/loading
of system settings.
At displacement
sensor startup
System
At displacement
sensor startup
System
275
Error Messages

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-ce1*tZw-c1*t

Table of Contents