Omron ZW-C1*AT User Manual page 47

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

Class
Name
Parallel
HIGH output
output
PASS output
LOW output
ALARM output
BUSY output
ENABLE output
BANK_OUT output
Parallel
ZERO input
input
RESET input
TIMING input
LED OFF input
BANK_SEL input
LOGGING input
ZW User's Manual
Description
This outputs judgment results - HIGH (HIGH threshold values < Measured value).
This outputs judgment results - PASS (LOW threshold values  Measured value  HIGH
threshold values).
This outputs judgment results - LOW (LOW threshold values > Measured value).
This turns ON when there is a system error.
This turns ON during sampling with the hold function enabled. It allows you to check
whether or not the self-trigger is functioning correctly.
It also turns ON during bank switching.
This turns ON when the sensor is ready for measurement.
This output is interlocked with the ENABLE indicator.
This outputs the currently specified bank number.
It expresses the bank number in combinations of BANK_OUT1, 2 and 3.
Bank Number BANK_OUT1
BANK1
OFF
BANK2
ON
BANK3
OFF
BANK4
ON
BANK5
OFF
BANK6
ON
BANK7
OFF
BANK8
ON
This is used to execute and clear a zero reset.
This resets all executing measurements and outputs.
While a RESET is being input, judgment output conforms to the non-measurement setting.
If this RESET input switches ON while the hold function is used, the state in effect before
the hold function was set will be restored.
This is a signal input from an external device that is used to time the hold function with the
continuous measurement function enabled.
This is a signal input from an external device that is used to time the measurement with the
trigger measurement function enabled.
This LED-OFF signal puts out the measurement LED.
While LED-OFF is being input, the analog output, binary output, and judgment output
conform to the non-measurement setting.
This is used for switching banks.
Specify the bank number in combinations of BANK_SEL1, 2 and 3.
However, if the bank mode is set to "JUDGEMENT", the bank cannot be switched at the
external signal input because the number of banks increases to 32.
Bank Number BANK_SEL1
BANK1
OFF
BANK2
ON
BANK3
OFF
BANK4
ON
BANK5
OFF
BANK6
ON
BANK7
OFF
BANK8
ON
This is used to start and end internal logging.
BANK_OUT2
BANK_OUT3
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
BANK_SEL2
BANK_SEL3
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
45