Omron ZW-C1*AT User Manual page 282

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

Event name
ZEROCLR input error
Meaning
ZEROCLR input processing was not executed correctly.
Source
EtherCAT master function module
Error attributes
Level
Effects
User program
Indicators
EtherCAT NET RUN
System-defined
Variable
variables
None
Cause and
Assumed cause
correction
ZEROCLRx input turned ON in the
FUN mode.
Attached
None
information
Precautions/
None
Remarks
280
Error Messages
Source details
Minor fault
Recovery
Continues
Operation
EtherCAT NET ERR
Data type
Correction
Switch to the RUN mode, and turn
ZEROCLRx input ON.
Event code
7496 0000Hex
Slave
Detection
timing
Error reset
Log category
(after
cancellation of
slave error)
ZEROCLR input processing is not executed.
EtherCAT LINK/ACT
Name
Prevention
When instructed
by the user
System
ZW User's Manual

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-ce1*tZw-c1*t