Zero reset
ON
ZERO input
OFF
Judgment output
(HIGH/PASS/LOW)
Item
T7
Input response time
T13
ZERO input time
T14
ZERO input cancel time
Explanation of operations
(1) The ZERO input is turned ON.
(2) After the ZERO input time, the ZERO input is turned OFF.
(3) After the ZERO input is turned OFF, the zero reset is executed and the judgment results reflected in the
measurement results are output.
(4) The ZERO input is turned ON.
(5) After at least the cancel time of ZERO input has passed, the zero reset is cancelled.
Operating Mode Switching
RUN
MODE
ON
BUSY output
OFF
ON
ENABLE output
OFF
Judgment output
(HIGH/PASS/LOW)
Analog output
Item
T3
Response time of analog output
T9
Measurement start response time
Explanation of operations
(1) After the mode is switched from RUN to FUN mode, the BUSY output and ENABLE output are turned OFF.
The judgment outputs all go OFF.
(2) The response time of analog output after the BUSY output is turned ON, the analog output is output
clamped.
(3) After the mode is switched from the FUN mode to the RUN mode, the BUSY output is turned OFF.
(4) Measurement is restarted and the ENABLE signal is turned ON, then the measurement results are output.
ZW User's Manual
(1)
(2)
(3)
(4)
T13
T7
Min.
2ms+T0
50 ms
1s
(1)
(2)
T3
FUN
All OFF
Min.
3 × T0
(5)
T14
Max.
3ms+T0 × 2
0.8s
(3)
(4)
T9
RUN
CLAMP
Max.
0.1 ms
Depends on the set conditions
Parallel I/O connection
157