Connectable Controller Models
Series
SYSMAC NJ
NJ501 or NJ301
SYSMAC CJ2
CJ2H or CJ2M
SYSMAC CJ1
CJ1H or CJ1G
CJ1M
SYSMAC CS
CS1H, CS1D, or CS1G
Setting Communications Specifications (EtherNet/IP)
Network Settings of the Sensor
This section describes how to set the network settings in the Displacement Sensor.
Explorer pane
: [Device group] | Sensor name | [System] | [System data] (Double-click)
Edit Pane
: [Ethernet communication settings] Icon | [Ethernet settings]
The following items can be set.
Item
IP address
Subnet mask
Default Gateway
ZW User's Manual
CPU Unit
Built-in port in CPU Unit
Compatible
Compatible (model with built-in
port only)
---
---
---
Description
Set the IP address of the Displacement Sensor.
Set the subnet mask.
Sets the default gateway.
Interface
EtherNet/IP Unit
CJ1W-EIP21
CJ1W-EIP21
CJ1W-EIP21
CJ1W-EIP21
CS1W-EIP21
Setting range
a.b.c.d
a: 1 to 223, b: 0 to 255,
c: 0 to 255, d: to 254
(Default: 192.168.250.50)
0.0.0.0 to 255.255.255.255
(Default: 255.255.255.0)
0.0.0.0 to 255.255.255.255
(Default: 0.0.0.0)
EtherNet/IP Connection
203