Omron ZW-C1*AT User Manual page 155

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

Hold (peak/bottom/peak to peak/average)
(1)
T5
T4
ON
TIMING input
OFF
ON
RESET input
OFF
ON
BUSY output
OFF
Judgment output
(HIGH/PASS/LOW)
Analog output
Item
T3
Response time of analog output
T4
TIMING input/RESET input minimum time
T5
Input response time
Explanation of operations
(1) The TIMING input is turned ON.
(2) During the TIMING input minimum time, when the TIMING input is ON, sampling is started and the BUSY
output is turned ON.
(3) The TIMING input is turned OFF.
(4) After the TIMING input turns OFF, sampling is ended and the judgment results are output. The BUSY output
is also turned OFF.
(5) After the judgment result output, the analog output is updated.
(6) The RESET input is turned ON. If the RESET input is turned ON during the RESET input minimum time, the
measured value is reset.
(7) The judgment result is reset.
(8) After the judgment result reset, the analog output is reset.
(9) The RESET input is turned OFF.
Important
When the setting for non-measurement is "CLAMP", if the sampling value is an abnormal value or an undetermined
*
value
, sampling is not executed. If sampling has been started, it is stopped. The output value is as follows.
• Hold the clamp value.
• To start and continue sampling even if a sampling value is an abnormal value or an undetermined value, set "KEEP"
as the non-measurement setting.
*: After the start of measurement, if measurement results are not obtained the number of times required to take the
average, the measurement result is not applied.
ZW User's Manual
(2)
(3)
(4) (5)
T5
T3
Min.
3ms+T0
2ms+T0
(9)
(6)
(7)
(8)
T4
T3
T5
Max.
0.1 ms
3ms+T0 × 2
Parallel I/O connection
153

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-ce1*tZw-c1*t

Table of Contents