Setting The Measurement Area - Omron ZW-C1*AT User Manual

Zw series displacement sensor confocal fiber type displacement sensor
Table of Contents

Advertisement

Setting the Measurement Area

The measurement area can be limited, setting upper line and lower line of selected area.
The measurement object can be measured stabile, cutting out the area that the object does not exist.
When the measurement object is set to "Glass," measurement may not be performed correctly as
measurement will be influenced by reflection from the rear surface. If this happens, set the measurement area
of each measurement surface so that they can be correctly measured.
Item
Setting item
Measurement
Upper line
area
Lower line
 Explorer pane
 Edit pane
 Sensing settings window : [Measurement area 1] or [Measurement area 2]
1
Set the [Upper line] and [Lower line] values
at [Measurement area].
Important
• Ensure that the setting values for the measurement area satisfy the following relationship: [Start] < [End].
• To set the measurement area using any value by the above method at [Measurement area 2], set [Area follow] at
[Area follow settings] to [OFF].
80
Setting Sensing
Setting value
Description
Measuring range
Set the measurement start position for the selected measurement area.
of Sensor Head
When the window for the selected measurement area is open, the start
[mm]
position can also be edited by dragging the start line on the line bright monitor.
Measuring range
Set the measurement end position for the selected measurement area.
of Sensor Head
When the window for the selected measurement area is open, the end
[mm]
position can also be edited by dragging the end line on the line bright monitor.
: [Bank] | [(Bank Data Name)] (double click)
: [Sensing setting] icon (
)
ZW User's Manual

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-ce1*tZw-c1*t

Table of Contents