linkDown
Port Security
Trap Name
portSecurityVioAction
RMON
Trap Name
risingAlarm
fallingAlarm
Start
Trap Name
coldStart
warmStart
DXS-1210 Series Smart Managed Switch CLI Reference Guide
(3) ifOperStatu
A notification is generated when port linkdown.
Binding objects:
(1) ifIndex
(2) if AdminStatus
(3) ifOperStatu
Description
When the port security trap is enabled, new MAC
addresses that violate the pre-defined port security
configuration will trigger trap messages to be sent
out.
Binding objects:
(1) portSecurityPort
(2) portSecurityVioCount
Description
The SNMP trap that is generated when an alarm
entry crosses its rising threshold and generates an
event that is configured for sending SNMP traps.
Binding objects:
(1)alarmIndex
(2)eventDescription
(3)alarmVariable
(4)alarmSampleType
(5) alarmValue
(6) alarmRisingThreshold
The SNMP trap that is generated when an alarm
entry crosses its falling threshold and generates an
event that is configured for sending SNMP traps.
Binding objects:
(1)alarmIndex
(2)eventDescription
(3) alarmVariable
(4)alarmSampleType
(5)alarmValue
(6) alarmFallingThreshold
Description
A coldStart trap signifies that the SNMPv2 entity,
acting in an agent role, is reinitializing itself and that
itsconfiguration may have been altered.
A warmStart trap signifies that the SNMPv2 entity,
acting in an agent role, is reinitializing itself such that
itsconfiguration is unaltered.
386
1.3.6.1.6.3.1.
1.5.3
OID
1.3.6.1.4.1.17
1.10.139.1.1.
8.1.2.1.1.4
OID
1.3.6.1.2.1.16
.0.1
1.3.6.1.2.1.16
.0.2
OID
1.3.6.1.6.3.1.
1.5.1
1.3.6.1.6.3.1.
1.5.2