Switch# show rmon statistics
Index 32, owned by it@domain.com, Data Source is eth 1/0/3
Received Octets : 234000, Received packets : 9706
Broadcast packets: 2266, Multicast packets: 192
Undersized packets: 213, Oversized
Fragments: 2, Jabbers: 1
CRC alignment errors: 0, Collisions: 0
Drop events : 0
Packets in 64 octets: 256, Packets in 65-127 octets : 236
Packets in 128-255 octets : 129, Packets in 256-511 octets : 10
Packets in 512-1023 octets : 38, Packets in 1024-1518 octets : 2200
Switch#
35-9
This command is used to enable the RMON trap state.
snmp-server enable traps rmon [rising-alarm | falling-alarm]
no snmp-server enable traps rmon [rising-alarm | falling-alarm]
Parameters
rising-alarm
falling-alarm
Default
By default, this option is disabled.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
This command enables RMON trap state.
Example
This example shows how to enable the sending of RMON traps for both the falling alarm and rising
alarm.
Switch# configure terminal
Switch(config)#snmp-server enable traps rmon
Switch(config)#
35-10
This command is used to display RMON trap state
show snmp-server traps rmon
DXS-1210 Series Smart Managed Switch CLI Reference Guide
snmp-server enable traps rmon
(Optional) Specifies to configure the rising alarm trap state.
(Optional) Specifies to configure the falling alarm trap state.
show snmp-server traps rmon
packets: 24