Chapter 16 MainteTool
16.1 MainteTool Outline
Access the Printlink5-IN shared folder from the service PC connected to the facility's network and use the
MainteTool in that shared folder to perform the various maintenance work.
Basic configuration
Use the Mainte_Tool folder shown in the diagram on the right above as a shared folder.
The Mainte_Tool folder is not shared on the network by default, so the settings need to be
Caution
changed. For more information, see
Use the MainteTool in the following cases:
When installing
•
When backing up the setup data after installation
•
When updating the application software version for DRYPRO 832 and Printlink5-IN (as necessary)
•
When restoring DRYPRO 832 or Printlink5-IN settings data from a backup file that has been saved (as
necessary)
•
When gathering DRYPRO 832 or Printlink5-IN logs (as necessary)
When repairing
•
When upgrading the DRYPRO 832 and Printlink5-IN application software
•
When collecting logs in the event of an error
•
When an error is detected in the image data
•
When checking the condition of detection and operation after replacing a sensor or motor
•
When the parts related to the exposure unit were replaced
•
When loading setup data from a backup file
16-2
"16.2.3 Sharing the Mainte_Tool Folder (Page 16-6)"