Konica Minolta drypro 832 Service Manual page 191

Laser imager
Hide thumbs Also See for drypro 832:
Table of Contents

Advertisement

7
Connect the connector (JP21) removed in
Be sure to push the connector all the way in when connecting it.
If the connector is not connected properly, an error will occur and, in some cases, smoke and/or
Caution
an odor may be generated.
8
Install the rear cover with reference to
Removing/Installing Rear
9
Return the supply tray and tray shutter to their original positions.
Take sufficient care when handling the tray shutter, as it may be impossible to insert if it
becomes deformed due to rough handling.
Caution
This is the end of the process of replacing the deodorant fan.
Chapter 9 Replacing Loading Parts in Heat Process Unit
4
Remove the connector (JP21).
Caution
5
Remove the deodorant fan.
• Four screws (M3×30)
6
Install a new deodorant fan.
• Four screws (M3×30)
step
4.
"
Installation Procedure (Page 3-19)"
Cover".
When removing the connector, do not pull by
the wires, but hold the tab on the connector
with your fingers.
Pulling by the wires too tightly can cause a
break.
in
"3.3.4
9-21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents