10
Install the lid removed in
• Nine screws (M3×6)
11
Install the control box assembly removed in
• Four screws (M3×6)
12
Install the control board duct unit assembly removed in
• Three screws (M3×6)
13
Connect the connector (JP24) removed in
Be sure to push the connector all the way in when connecting it.
If the connector is not connected properly, an error will occur and, in some cases, smoke and/or
Caution
an odor may be generated.
14
Connect the connectors removed in
supply (JP52).
Be sure to push the connector all the way in when connecting it.
If the connector is not connected properly, an error will occur and, in some cases, smoke and/or
Caution
an odor may be generated.
15
Install the connector cover removed in
16
Install the LAN cover and film ejection tray with reference to
3-11)"
in
"3.3.2 Removing/Installing Film Ejection
This is the end of the process of replacing the compact flash.
Chapter 11 Replacing Loading Parts in Main Unit
step 7
on the control box.
step
6.
step
4.
step 3
to MEC IF (CCN5), exposure IF (CCN6), and power
step
2.
Tray".
step
5.
"
Installation Procedure (Page
11-13