8
Click the [Next(N)] button.
The "DENSITOMETER(STEP3)" window appears.
9
Enter a value equals to the density measured in
one-byte numbers in [01] - [12] in the "DENSITOMETER (STEP3)" window,
Example:
If the (01)st density value is 0.21, enter "21" in the 01 field.
If the (12)th density value is 3.16, enter "316" in the 12 field.
Entering and saving an abnormal or incorrect value can cause density correction data
corruption, making it impossible to perform density correction properly. Take care not to enter
Caution
an abnormal or incorrect value.
Example of abnormal or incorrect values
Values deviating greatly from the measured value
The density value was 1.25, but "215" was entered by mistake.
The density value was 1.25, but an abnormal value of "400" was intentionally entered.
Chapter 15 DRYPRO 832 Utility Tool
7
Measure the density of the printed densitometer
calibration patterns (01) - (12), using an external
densitometer.
When measuring the film density, make sure
to standardize the measuring surface of film
Caution
(front/back side).
If the measuring surface is not standardized,
the results of measuring the film density may
vary, depending on the model of the
densitometer.
For details of how to measure the density, see the
instruction manual that comes with the
Note
densitometer.
Step
7, which was increased by 100-fold, in
15-45