Konica Minolta drypro 832 Service Manual page 403

Laser imager
Hide thumbs Also See for drypro 832:
Table of Contents

Advertisement

Error
Error
Error
Message (Display
Level
Code
Characters)
F
3007
HPRO Error
F
3008
HPRO Error
F
3009
HPRO Error
F
300B
HPRO Error
E
3012
Temperature error
E
3013
Temperature
error
E
3014
Temperature
error
E
3022
Temperature
error
E
3023
Temperature
error
Error contents
Check the AD_ERR signal every 0.1
seconds, and an error occurs if an
anomaly is detected
Check the connector disconnect signal for the
heater temperature sensor every 0.1 seconds,
and an error occurs if an anomaly is detected
Check the sensor detection of wire malfunction
signal for density correction every 0.1 seconds,
and an error occurs if an anomaly is detected
The density correction sensor A/Dvalue
has a fixed upper value.
When the pre-heating C2 30 second
moving average temperature is compared
to 100°C, an error occurs when the
temperature is 5°C higher when Ready
and 10°C higher when in PRINT.
When the pre-heating C2 30 second
moving average temperature is compared
to 100°C, an error occurs when the
temperature is 5°C lower when Ready
and 10°C lower when in PRINT.
Irrespective of the status of the machine,
check the temperature of preheat C2 every 1
seconds, and if the temperature is continually
147°C for 5 seconds, an error occurs
When the heating temperature 30 second
moving average temperature is compared
to 130°C, an error occurs when the
temperature is 5°C higher when Ready
and 10°C higher when in PRINT.
When the heating temperature F 30
second moving average temperature is
compared to 130°C, an error occurs when
the temperature is 5°C lower when Ready
and 10°C lower when in PRINT.
Chapter 17 Troubleshooting
Error Support: Service
1.
Replace HPRO unit
2.
Replace mechanical control board
3.
Replace wire bundle between mechanical control board and HPRO unit
1.
Check connection between mechanical control board and HPRO
unit
2.
Replace HPRO unit
3.
Replace mechanical control board
4.
Replace wire bundle between mechanical control board and
HPRO unit
1.
Replace HPRO unit
2.
Replace mechanical control board
3.
Replace wire bundle between mechanical control board and
HPRO unit
1.
Check HPRO OFFSET and mechanical control offset
2.
Check the connection between the H-DRVboard and mechanical
control board
3.
Check connection between mechanical control board and HPRO unit
4.
Check conductance of the power cable
5.
Check voltage
6.
Replace H-DRV board
7.
Replace heat process unit
8.
Replace mechanical control board
9.
Replace the wire bundle between the H-DRVboard and
mechanical control board
10. Replace wire bundle between mechanical control board and HPRO unit
1. Check HPRO OFFSET and mechanical control offset
2. Check whether the short-circuit breaker (domestic)
or circuit protector (domestic) is OFF
3. Check the connection between the H-DRVboard and
mechanical control board
4. Check connection between mechanical control
board and HPRO unit
5. Check conductance of the power cable
6. Check voltage
7. Replace H-DRV board
8. Replace heat process unit
9. Replace mechanical control board
10. Replace the wire bundle between the H-DRVboard
and mechanical control board
11. Replace wire bundle between mechanical control
board and HPRO unit
1. Check HPRO OFFSET and mechanical control offset
2. Check the connection between the H-DRVboard and
mechanical control board
3. Check connection between mechanical control
board and HPRO unit
4. Check conductance of the power cable
5. Check voltage
6. Replace H-DRV board
7. Replace heat process unit
8. Replace mechanical control board
9. Replace the wire bundle between the H-DRVboard
and mechanical control board
10. Replace wire bundle between mechanical control
board and HPRO unit
1. Check HPRO OFFSET and mechanical control offset
2. Check whether the short-circuit breaker (domestic)
or circuit protector (domestic) is OFF
3. Check the connection between the H-DRVboard and
mechanical control board
4. Check connection between mechanical control
board and HPRO unit
5. Check conductance of the power cable
6. Check voltage
7. Replace H-DRV board
8. Replace heat process unit
9. Replace mechanical control board
10. Replace the wire bundle between the H-DRVboard
and mechanical control board
11. Replace wire bundle between mechanical control
board and HPRO unit
17-15

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents