Chapter 7 Replacing Sub Scan Unit Loading Parts
7-28
3
Remove the connector (JP10).
When removing the connector, do not pull by the
wires, but hold the tab on the connector with your
Caution
fingers.
Pulling by the wires too tightly can cause it to
break.
4
Remove the exposure unit mounting frame unit
assembly.
• Four screws (M4×6)
5
Remove the cover.
• Two screws (M3×6)
6
Remove the Moderation belt by loosening the belt
tension.
If you touch the belt with bare hands, it can
cause dust and dirt to adhere to the belt,
Caution
resulting in pitch irregularity and image
inconsistencies.
When removing the belt, wear gloves.
7
Loosen the set screw and remove the pulley.
• One set screw (M3×6)