Konica Minolta drypro 832 Service Manual page 223

Laser imager
Hide thumbs Also See for drypro 832:
Table of Contents

Advertisement

9
Connect Faston terminals (NF1-1, NF1-2, NF1-3, NF1-4, NF1-5, NF1-6, and NF1-7) removed
in
step
6.
10
Install the lid removed in
• Four screws (M3×6)
11
Install the left cover with reference to
Removing/Installing Left
Chapter 11 Replacing Loading Parts in Main Unit
4
Remove the left cover.
• Four screws (M4×8)
Slide the left cover upward so that the tabs (two locations)
on the inside of the left cover detach from the main unit, and
remove the cover.
Note
5
Remove the lid from the noise filter.
• Four screws (M3×6)
6
Remove Faston terminals (NF1-1, NF1-2, NF1-3,
NF1-4, NF1-5, NF1-6, and NF1-7).
The NF1-1 (black) and NF1-2 (white) are connected to the
to main power supply.
The NF1-3 (black) and NF1-6 (white) are connected to the
ground-fault circuit interrupter.
The NF1-4 (black) and NF1-7 (white) are connected to the
multiple power supply.
The NF1-5 (green) is connected to FG.
7
Remove the noise filter.
• Six screws (M4×8)
8
Install a new noise filter.
• Six screws (M4×8)
step 5
on the noise filter.
"
Installation Procedure (Page 3-23)"
Cover".
Remove two screws on the upper part of the left
cover and loosen two screws on the lower part.
in
"3.3.6
11-23