Error
Error
Error
Message (Display
Level
Code
Characters)
F
8010
Application
error
F
8080
Application
error
F
8081
Application
error
F
8082
Application
error
F
8083
Application
error
F
8084
Application
error
F
8090
Application
error
F
8091
Application
error
F
8092
Application
error
F
8093
Application
error
F
80A0
Application
error
F
80A1
Application
error
F
80A2
Application
error
F
8100
Application
error
F
8101
Application
error
F
8102
Application
error
F
8104
Application
error
F
8105
Application
error
F
8200
Print control
error
17-26
Error contents
Cannot receive 1A from mechanical
control.
Retry of print server update is over
Cannot open retry file.
Cannot write into retry file.
Cannot close retry file.
Cannot delete retry file.
Error updating the print version, or there
is no file.
Cannot open print version update file.
Cannot write print update file to FLASH-
ROM.
Cannot read print version update file.
Print driver device error
Print driver device open error
No pixel clock output
Flash ROM delete error
Flash ROM comparison error
Memory error
Reception error
Received data error
Driver: Device not registered
Error Support: Service
1. Check for disconnected connectors of
communication cable between main ? mechanical
control (control board side, mechanical control side)
2. Check communication cable between main ?
mechanical control for broken wires
3. Replace cables between main mechanical control
4. Replace the mechanical control board
5. After replacing the control box, restore the settings
After replacing the control box, restore the settings
Replace the main board
Replace the mechanical control board
After replacing the control box, restore the settings
1. Check for disconnected connectors of
communication cable between main-mechanical
control (control board side, mechanical control side)
2. Check communication cable between main-
mechanical control for broken wires
3. Replace cables between main-mechanical control
4. Replace the mechanical control board
5. After replacing the control box, restore the settings
The cause of this error is either software or hardware.
Either reset the error, or switch the power OFF/ON.
If this does not correct the problem, either upgrade the
software or replace the control box.