Chapter 5 Replacing Tray Unit Loading Parts
7
Remove the connector cover.
• One screw (M3×6)
If the Lispl-832 is connected, remove the
connector cover after removing the connector
Note
(JP16, JP 26).
8
Remove the cover.
・ Four screws (M3×6)
Proceed to
step
10.
9
Remove the Lispl-832 connector cover.
・ Four screws (M3×6)
Remove the connectors (JP16, JP26) before
removing the connector cover.
Note
10
Remove the connectors.
To replace the tray unit tray detection sensor, remove the
connector (JP55, JP44).
To replace the Lispl-832 tray detection sensor, remove the
connector (JP63, JP44).
When removing the connector, do not pull by
the wires, but hold the tab on the connector
Caution
with your fingers.
Pulling by the wires too tightly can cause a
break.