When the server PC is Printlink5-IN
START
Exit the DRYPRO 832
Refer to
main unit
power source breaker OFF.
Server PC Installation
Refer to
Start the server PC
Start the server PC (Printlink5-IN).
Caution
Upgrading server PC
Refer to
newer version than [V1.02R00] using the MainteTool.
If the upgrade of the server PC completes normally, the server PC will automatically restart.
Restore the setup
Refer to
If the restore of the server PC completes normally, the server PC will automatically restart.
Caution
Start the DRYPRO 832
Refer to
starts normally.
Note
"3.2.1 How to Exit" in the operation manual
Printlink5-IN operation manual,
and install server PC.
Do not connect the DRYPRO 832 and Printlink5-IN in powered up state until
the server PCupgrade has been completed.
If you have connected the DRYPRO 832 and Printlink5-IN in powered up state
before upgrading the software, after checking following message in the
DRYPRO 832 operation panel, turn OFF the DRYPRO 832 by pressing the
operation switch, then turn OFF the power breaker directly, and then perform
the next procedure, "Upgrade of Server PC".
"INITIALIZING"
Refer to operation manual for messages displayed on the operation panel.
"16.4 Upgrade Information (Page
16-12)", and upgrade the Printlink5 software to a
"16.6 Restoring Settings (Page 16-26)"
Perform the restore for the Printlink5-IN. Do not restore DRYPRO 832.
If you have restored DRYPRO 832, it will be set to setting from the previous
backup. Change the setting to the one with the changes made after previous
backup.
"3.1.1 How to Start" in the operation
If the MEC upgrade is performed at startup, the startup time may take a few minutes
longer than normal.
Chapter 17 Troubleshooting
to exit the DRYPRO 832 and switch the
to restore the setup.
manual, and check whether the DRYPRO 832
17-103