ELECTRIC STARTER
Install a new O-ring into the thermostat housing
groove.
Install the thermostat housing to the cylinder head.
Install and tighten the mounting bolts.
Install the following:
- Thermostat housingithermostat (page 6-7).
- Throttle body (page 5-71).
Fill the system with the recommended coolant (page
STARTER RELAY SWITCH

OPERATION INSPECTION

Remove the seat (page 2-21.
Shift the transmission into neutral.
Turn the ignition switch t o "ON" and engine stop
switch t o "RUN".
Push the starter switch button.
The coil is normal if the starter relay switch clicks.
If you don't hear the switch "click", inspect the relay
switch using the procedure below.
GROUND LINE INSPECTION
Disconnect the relay switch connector.
Check
(ground line) terminal and ground.
If there is continuity when the transmission is i n neu-
or
tral
stand switch is retracted, the ground circuit is normal
(in neutral, there is a slight resistance due t o the
diode).
18-10
for
continuity between the Green/Red wire
when the clutch is disengaged and the side
I
STARTER RELAY SWITCH
RELAY SWITCH CONNECTOR