Remove the EGCV from the valve body.
Remove carbon deposits from the EGCV and valve
body.
Do not use any cleaning solution to clean the EGCV
bushings.
Do
not apply any lubricant to the EGCV bushings.
Check that the EGCV for wear or damage.
Check that the EGCV body for wear or damage.
EGCV SHAFT BUSHING REPLACEMENT
Remove the valve body side EGCV bushing and cap
using the following tools.
TOOL:
Remover, 14 x 16 rnm
Install the EGCV cap into the EGCV body until it seats
using the special tool.
TOOLS:
Installer shaft guide
Installer shaft
Press the
EGCV
bushing until its
end is beiow 0.3
-
-
0
5
mm
01
Press the EGCV bushing in using the special tool.
valve body sur-
face as shown
TOOLS:
installer shaft guide
Installer shaft
FUEL SYSTEM (Programmed Fuel injection)
INSTALLER SHAFT
(U.S.A. only)
(U.S.A. only)
(U.S.A. only)
(U.S.A. only)
,
CAP
0.3 - 0.5 m m (0.01
REMOVER
-
0.02 in)
I
5-99