FUEL SYSTEM (Programmed Fuel Injection)
Measure the resistance between the servo motor 6P
(Natural) connector terminals.
Connection: YellowIRed
Standard: 5 k R
Connection: Light greenlPink
Standard: 0
If the resistance is out of range, replace the servo
motor.
INSTALLATION
Connect the servo motor 6P (Natural) connector.
Short the service check connector (page 5-93).
servo motor,
S
I
not necessary to
Turn the ignition switch to "ON".
do
this procedure
The servo motor turns, then stops.
Secure the servo motor pulley at this position using a
3 -m m socket bolt as shown.
Socket bolt, 3 x 28
Parts number: 31420-MCJ-640
Connect the EGCV control cables t o each position,
then connect the intake valve control cable.
Adjust the EGCV and air intake valve control cables
(page 5-93).
Remove the 3-mm socket bolt f r o m the servo motor
p u I ley.
Install the servo motor onto the bracket.
Install and tighten the servo motor mounting bolt.
-
-
-
5 k R
mm:
3-mm SOCKET BOLT
3 m m SOCKET BOLT
\
I
PULLEY