FUEL SYSTEM (Programmed Fuel Injection)
PGM-FI MIL 18 BLINKS (CAM PULSE GENERATOR)
Turn the ignition switch to
Place the motorcycle on its side stand.
Turn the ignition switch to "ON" and check that
the MIL blinks.
Turn the ignition switch to
"OFF".
engine stop switch to
Disconnect the cam pulse generator 2P connec-
tor.
Turn the ignition switch to
Check the continuity between the cam pulse
generator connector terminal and ground.
-
Connection: Gray
Ground
-
Black
Ground
Standard: No continuity
5-38
"OFF".
18 blinks
"OFF"
and the
"OFF".
No continuity
Does not blink
Loose or poor contact on the cam pulse generator
Continuity
Faulty cam pulse generator