Apply a locking agent t o the mainshaft bearing set
plate bolt threads.
Install the mainshaft bearing set plate with its "OUT-
SIDE'' mark facing out.
Tighten the mounting bolts to the specified torque.
TORQUE: 12 Nom (1.2 kgforn,
Install the removed parts i n the reverse order of
removal.
11-14