Check that the EGCV cable pulley is moved t o 180"
(pulley index line facing down) at about 8,000 rpm.
Also check that the intake flap valve is opened at the
same time.
If the intake and EGCV position is incorrect, adjust the
cables (see below).
If the intake and EGCV operation is incorrect, check
for each related parts.
CABLE ADJUSTMENT
Remove the seat (page 2-2).
Turn the ignition switch t o "ON".
Short the service check connector with a jumper wire.
EGCV CONTROL CABLE ADJUSTMENT
Make sure that the EGCV cable guide pulley index line
is aligned with the EGCV cover index line.
If the index lines do not align, adjust the EGCV control
cables.
Fully loosen the No.1 adjusting cable (spring
equipped cable) lock nut and adjusting nut.
FUEL SYSTEM (Programmed Fuel Injection)
0 '
90'
180'
I
INDEX LINES
ADJUSTING NUT
LOCK N U T
I

Hide quick links: