Directly Entering The Parameter Number And Value - Siemens SINAMICS G120 Operating Instructions Manual

Low voltage converter with the cu240b-2 and cu240e-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Appendix
A.3 Handling the BOP 2 operator panel
Procedure
To change an indexed parameter, proceed as follows:
1. Select the parameter number.
2. Press the OK key.
3. Set the parameter index.
4. Press the OK key.
5. Set the parameter value for the selected index.
You have now changed an indexed parameter.
A.3.3

Directly entering the parameter number and value

Directly select the parameter number
The BOP-2 offers the possibility of setting the parameter number digit by digit.
Precondition
The parameter number is flashing in the BOP-2 display.
Procedure
To select the parameter number directly, proceed as follows:
1. Press the OK button for longer than five seconds.
2. Change the parameter number digit-by-digit.
If you press the OK button then the BOP-2 jumps to the next
digit.
3. If you have entered all of the digits of the parameter number,
press the OK button.
You have now entered the parameter number directly.
490
Converter with the CU240B-2 and CU240E-2 Control Units
Operating Instructions, 01/2016, FW V4.7 SP6, A5E34259001B AC