dC132 Device ID and Billing Data

Purpose
To view and, if required, synchronize the serial and product numbers between the drive PWB
and ESS PWB when a new drive PWB or ESS PWB has been installed.
The serial and product numbers are held at the following locations:
EPROM on the drive PWB (IOT).
EPROM on the ESS PWB (SYS1).
ESS PWB (SYS2).
NOTE: This function must only be used when a failure has occurred. When the values at the
three locations (IOT, SYS1, SYS2) are the same, there is no need to continue with the proce-
dure.
Procedure
1.
Enter Diagnostics,
GP
1.
2.
Touch dC132 Device ID and Billing Data.
3.
To change the values, touch IOT, SYS1 or SYS2.
4.
Follow the on screen instructions to enter the required values, then touch OK.
5.
Exit diagnostics,
GP
1.
Launch Issue
Xerox® VersaLink® B7025/B7030/B7035 Multifunction Printer

dC135 HFSI Counter

Purpose
To view the counters for high frequency service items (HFSI).
Procedure
1.
Enter Diagnostics,
GP
1.
2.
Touch dC135 HFSI Counter.
3.
Enter the relevant Chain-Link number or select the component from the list.
4.
Touch Details. The Details screen will open, displaying the part name, current value,
replacement data and the specified life.
5.
Refer to
Table 1
to observe the status of the items.
6.
To reset an HFSI value:
a.
Touch Reset.
b.
The Reset Current Value screen will open.
c.
Touch Yes to reset the NVM value.
NOTE: The three previous replacement values will be modified.
7.
To edit the specified life of an HFSI:
a.
Touch Spec Life.
b.
The Spec Life screen will open.
c.
Enter the new value.
d.
Touch OK.
8.
Touch Close to return to the HFSI Counter screen.
9.
Touch Close to return to the Diagnostics screen.
10. Exit diagnostics,
GP
1.
Chain-Link
Name
954-800
Tray 1 Feed/Retard/Nudger Rolls
954-801
Tray 2 Feed/Retard/Nudger Rolls
954-802
Tray 3 Feed/Retard/Nudger Rolls
954-803
Tray 4 Feed/Retard/Nudger Rolls
954-804
HCF1 Feed/Retard/Nudger Rolls
954-805
MSI (Bypass Tray) Feed Roll/Retard
954-820
BTR Unit
954-850
Fusing Unit Print Count
954-851
Fusing Unit Time Count
955-806
Feed Count
955-807
Simplex Feed Count
955-808
Duplex Feed Count
955-810
I/L Open Count
955-812
TA Clutch On-Count
955-826
Nip Sol On-Count
April 2017
6-47
Table 1 HFSI Details
Spec Life
300K Feeds
300K Feeds
300K Feeds
300K Feeds
300K Feeds
50K Feeds
200K Feeds
175K Feeds
18000K seconds
200K Feeds
360K Feeds
360K Feeds
180K
1080K
500K
General Procedures and Information