Ricoh OR-C1 Field Service Manual page 548

Table of Contents

Advertisement

4. Appendix: Service Program Mode Tables
Permissible Number
Sets the number of attempts to attack the system with random passwords to gain illegal
1
access to the system.
[0 to 100 / 30 / 1 attempt]
Detect Time
2
Sets the time limit to stop a password attack once such an attack has been detected.
[1 to 10 / 5 / 1 sec.]
5416*
Access Information
4
Access User Max Number
Limits the number of users used by the access exclusion and password attack detection
1
functions.
[50 to 200 / 200 / 1 users]
Access Password Max Number
Limits the number of passwords used by the access exclusion and password attack
2
detection functions.
[50 to 200 / 200 /1 passwords]
Monitor Interval
3
Sets the processing time interval for referencing user ID and password information.
[1 to 10 / 3 / 1 sec.]
5417*
Access Attack
Access Permissible Number
Sets a limit on access attempts when an excessive number of attempts are detected for
1
MFP features.
[0 to 500 / 100 / 1]
Attack Detect Time
2
Sets the length of time for monitoring the frequency of access to MFP features.
[10 to 30 / 10 / 1 sec.]
190

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D120D139D140D141D121D122

Table of Contents