Type
CPU/Memory Error
• System firmware problem
[0702]
• Defective RAM-DIMM
[0709]
• Defective controller
[070A]
1. Reinstall the controller system software.
2. Replace the RAM-DIMM.
3. Replace the controller.
No.
Type
Self-diagnostics error: ASIC
821
D
[XXXX]: Detailed error code
ASIC error
The write-&-verify check error has occurred in the ASIC.
[0B00]
Defective ASIC device
Replace the controller.
ASIC detection error
The I/O ASIC for system control is not detected.
[0B06]
Defective ASIC
Defective North Bridge and PCI I/F
Replace the controller board.