Ricoh OR-C1 Field Service Manual page 396

Table of Contents

Advertisement

2. Appendix: PM Tables
Item
APS Sensor
Around the Drum
Transfer/Separation Unit
2
ID Sensor
PCU
Drum
Charge Roller
Cleaning Roller
Cleaning Blade
Pick-off Pawls
Developer
Paper Feed
Registration Rollers
Paper Feed Roller
Separation Roller
Pick-up Roller
Paper Feed Guides
Relay Rollers
Dust collection box
Fusing Unit and Paper Exit
Fusing Entrance and Exit
Guide Plates
38
EM
120K
240K
C
C
R
R
C
C
R
R
R
R
R
R
R
R
R
R
R
R
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
C
360K
NOTE
C
Dry cloth or blower brush
R
Perform the ID sensor initial setting
C
(SP2-935) after cleaning (blower
brush)
R
R
Do SP2801. This initializes the
R
developer and resets the TD and
ID sensor outputs to their defaults.
R
It also resets the PCU counter.
R
R
C
Clean with water
C
Dry cloth
C
Dry cloth
C
Dry cloth
C
Clean with alcohol.
C
Clean with water.
C
Remove, empty, clean
C
Clean with water or alcohol.